INSULATING GLOVES for electrical works
Our full range of insulating gloves for live working complies with the specifications of the European standard EN 60903:2003 and the international standard IEC 60903:2002.
Likewise, our production is subjected to a system for ensuring EC quality of production by means of monitoring to implement article 11b of the 89/686/EEC directive relating to Personal Protective Equipment which classifies insulating gloves for live working in category III (mortal risks).
Special properties (sampling test)
Resistance to acid :
conditioning of gloves by immersion for 8 hours at 23 2 C in a sulphuric acid solution at 32 Baume
The tensile strength and elongation at break values must be at least equal to 75% of those of non-conditioned gloves.
The gloves must pass the proof test voltage.
Resistance to oil :
conditioning by immersion in oil (Iiquid 102) for 24 hr at 70 2 C
The tensile strength and elongation at break values must be at least equal to 50% of those of non-conditioned gloves.
The gloves must pass the proof test voltage.
Resistance to ozone :
conditioning of gloves in a chamber for 3 hours at 40 2C and in a 1 mg/m3 ozone concentration
The gloves must not present any cracking
The gloves must pass the proof test voltage.
Resistance to very low temperatures :
conditioning of gloves for 24 hours at -40 3C
The tests are satisfactory if no tearing, breaking or cracking after folding is visible on the cuff and if the gloves pass the proof test voltage.
KAMI MELAYANI PEMESANAN KESELURUH KOTA-KOTA DI INDONESIA Surabaya, Bali, Sidoarjo, Malang, Semarang, Yogyakarta, Pekalongan, Cirebon, Tangerang, Jakarta, Bandung, Sumatra, Aceh, Lampung, Medan, Riau, Batam, Jambi, Padang, Kalimantan, Samarinda, Pekanbaru, Bengkulu, Makasar, Sulawesi, Irian jaya,Papua, Bangka Belitung, Banten, Jabar, Jateng, Jatim, Ntt, Ntb, Gorontalo, maluku DLL